FRIGO TURBO K......R134a.....270 kW

MAIN FEATURES
Water cooled liquid chiller.
1 size designed for installation in parallel.
EER 4,39.
ESEER 7,16.
Oil-free centrifugal compressors with magnetic levitation bearings.
Inverter driven.
R134a Refrigerant charge.
Single refrigerant circuit.
Electronic expansion valve.
Plate type heat exchangers.
Suitable for indoor installation.

MAIN BENEFITS
Compact version with plate heat exchangers. 270kW at just 1,3m2.
Installation in parallel of many units, to achieve high cooling capacity in reduced spaces.
No need of power factor correction.
Minimum starting current (LRA)
High ESEER.
Quiet operation.
Microprocessor control system with 7” touch screen display.
Extremely easily of maintenance.
Complete set of components dedicated to the safety of the unity.
Eurovent Certification.
 
INDOOR INSTALLATION
The machines are designed for indoor installation.
DESIGNED FOR INSTALLATION IN PARALLEL MAGNETIC LEVITATION CENTRIFUGAL COMPRESSOR
The TURBO FL liquid chillers are equipped with two-stage centrifugal
compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in  a narrowing of the cooling load. The compressors of the TURBO FL liquid chillers are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication.

WORKING LIMITS IN COOLING MODE
Chilled water outlet temperature: 4÷18°C Condenser outlet water temperature: 20÷52°C
 
the integrated cooling circuit.
Electric motor thermal protection via internal winding temperature sensors.
Electronic integrated control for operation and alarms status.
Sensor on refrigerant discharge for temperature monitoring.
Inner sensors for electronic components and inverter temperature control.
Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply.
Degree of protection: IP54.
 
Menu with protection password.

HYDRAULIC CONNECTIONS OF HEAT EXCHANGERS
The hydraulic connections with flange (FL) are not supplied with counter flange.
The hydraulic connections with grooved end are not supplied with flexible
joint (optional accessory).
 

EVAPORATOR
Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel.
Anticondensate insulation made of polyurethane.
Temperature sensors on water inlet and outlet.
Hydraulic connections with grooved end arranged for flexible joint (the flexible joint and the adapter pipe are optional accessories).

CONDENSER
Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel.
Anticondensate insulation made of polyurethane.
Hydraulic connections with grooved end arranged for flexible joint (the flexible joint and the adapter pipe are optional accessories).

REFRIGERANT CIRCUIT
Components for each refrigerant circuit:
Capacitive level sensor connected to the driver of the expansion valve.
Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator.
Electronic by-pass valve for compressor start.
Non return valve on by-pass line for compressor start.
Sight glass.
Filter dryer on liquid line.
Service valve on liquid line.
Service valve on gas discharge.
Non return valve on gas discharge.
Safety valve on low pressure side.
Safety valve on high pressure side.
Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure.
High pressure safety switch with manual reset.
Refrigerant circuit with copper tubing with anticondensate insulation of the suction line
Plastic capillary hoses for pressure sensors connection.
R134a refrigerant charge.
 
Chillers

 

 

DESIGNED FOR INSTALLATION IN PARALLEL
The “K” version is designed for installation in parallel, to achieve high cooling capacity in reduced spaces with high silentness need.