![](http://rcgroup-ukraine.com.ua/sites/default/files/styles/68x68/public/3835567fbb80003167f53a57e7f98423.jpg?itok=28S2-XLb)
Official importer "Aclima" in Ukraine
MAIN FEATURES
Multifunction chiller.
7 models available, for a wide selection opportunity..
Average step of 28kW.
EER up to
COP up to
ESEER up to
Scroll compressors.
Single refrigerant circuit.
R410A refrigerant charge.
Plate type heat exchanger.
Electronic expansion valves.
Suitable for indoor installation.
ELECTRONIC EXPANSION VALVE
The electronic expansion valves are synonymous of an higher energy efficiency and stability of the system.
WORKING LIMITS IN COOLING MODE
Evaporator chilled water outlet temperature: -10÷15°C Ambient temperature: -12÷18°C
WORKING LIMITS IN HEATING MODE
Condenser hot water outlet temperature: 30÷55°C Ambient temperature: -10÷35°C
MAIN BENEFITS
Units equipped with two scroll compressors on refrigerant circuit to reach a high efficiency.
Reduces noise emission
Easily of maintenance.
WORKING LOGIC REFRIGERANT CIRCUIT
Components for each refrigerant circuit:
TRIPACK
The TRIPACK is a water cooled, heat pump liquid chiller for the production of chilled water, hot water and hot domestic hot water (multifunction). In working condition 2, the production of chilled water and domestic hot water is simultaneous. In working condition n.4, the unit gives priority to the domestic hot water production. Only when this priority is satisfied the system starts automatically to produce hot water for heating.
Reversing valve for refrigeration cycle inversion.
Electronic expansion valve. The valve allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure.
The expansion valve is equipped with energy reserve to allow the closure of the valve in the event of lack of power supply.
Sight glass.
Filter dryer on liquid line.
Liquid receiver with service valve and safety valve.
Service valves on liquid line and gas discharge.
Safety valve on low pressure side.
Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure.
High pressure safety switch with manual reset.
Oil drainage and oil recovery systems.
Refrigerant circuit with copper tubing with anticondensate insulation of the suction line.
Plastic capillary hoses for pressure sensors connection.
R410A refrigerant charge.
MAIN COMPONENTS
FRAMEWORK
Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders.
Colour: RAL 9002
COMPRESSORS
Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410A refrigerant.
ON / OFF capacity control (0 / 100% each compressor).
2-pole 3-phase electric motor with direct on line starting.
Phase sequence electronic relay.
Crankcase heater.
Electric motor thermal protection via internal winding temperature sensors.
Rubber supports.
PLANT SIDE HEAT EXCHANGER
Copper brazed plate type with cover plates, plates and connections in AISI
316 stainless steel.
Anticondensate insulation made of polyurethane.
Temperature sensors on water inlet and outlet.
Differential water pressure switch for water flow control.
EXHAUSTION SIDE HEAT EXCHANGER
Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel.
Temperature sensor on water outlet.
0÷10V proportional signal to manage the 2-way motorized valve for the condensing control (summer working mode) and evaporating control (winter working mode).
TOTAL HEAT RECOVERY HEAT EXCHANGER
Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel:
Anticondensate insulation made of polyurethane.
Temperature sensors on water inlet and outlet.
Differential water pressure switch for water flow control.
ELECTRICAL PANEL
In accordance with EN60204-1 norms, suitable for indoor installation complete
with:
Main switch with door lock safety.
Magnetothermic switch or fuses for each compressor.
Contactors for each load.
Transformer for auxiliary circuit and microprocessor supply.
Panel with machine controls.
Summer / Winter working mode selector.
Power supply 400/3/50.
CONTROL SYSTEM
MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes:
Voltage free contact for remote general alarm.
Main components hour-meter.
Clock card for alarms date and time displaying and storing.
Nonvolatile “Flash” memory for data storage.
Menu with protection password.
LAN connection.
HYDRAULIC CONNECTIONS OF HEAT EXCHANGERS
The heat exchangers’ threaded hydraulic connections are available up to a diameter of 3 “ included, and correspond to ISO 228/1 – G M.
The pipes’ threaded hydraulic connections are available up to a diameter of
3 “ included, and correspond to ISO 7/1 – R.
The hydraulic connections with flange (FL) are not supplied with counter
flange.
The hydraulic connections with grooved end are not supplied with flexible joint (optional accessory).