SMART HP PF ..... 12,1 ÷ 41,4 kW

MAIN FEATURES
Air / water reversible heat pump.
9 models available, for a wide selection opportunity..
Average step of 3kW.
EER up to 2,63.
COP up to 3,47.
ESEER up to 3,23.
Scroll compressor.
R410A Refrigerant charge.
Single refrigerant circuit.
Plate type heat exchanger.
Plug fans EC.
Single air circuit.
Suitable for indoor installation.

MAIN BENEFITS
Availability of kit for the reduction of the noise.
Availability of pumping groups.
Availability of partial heat recovery system.
Plug fans EC for an high efficiency.
Easily of maintenance.
Eurovent Certification.
 
FANS WITH BRUSHLESS TYPE EC MOTOR
These electric motors are ensuring high performances, minimum energy consumption and total absence of electromagnetic noise.

INDOOR INSTALLATION
The machines are designed for indoor installation and ducting for air suction and discharge.
For outdoor installation the use of the dedicated optional kit is mandatory The machine must be installed under a cover or anyway protected agains atmospherics agent.

WORKING LIMITS IN COOLING MODE
Chilled water outlet temperature: -8÷18°C Ambient temperature: -10÷46°C

WORKING LIMITS IN HEATING MODE
Hot water outlet temperature: 25÷50°C Ambient temperature: -7÷20°C
 

 
MAIN COMPONENTS
FRAMEWORK
Base, self supporting frame and paneling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders.
Colour: RAL 9002

COMPRESSORS
Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410A refrigerant.
ON / OFF capacity control (0 / 100% each compressor).
2-pole 3-phase electric motor with direct on line starting.
Crankcase heater.
Electric motor thermal protection via internal winding temperature sensors.
Terminal box with IP54 enclosure class.
Rubber supports.

EVAPORATOR
Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel:
Anticondensate insulation made of neoprene.
Temperature sensors on water inlet and outlet.
Differential water pressure switch for water flow control.
Antifreeze heater.

CONDENSING COIL
Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops.
Frame in galvanized steel.

FANS SECTION
Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fan).
Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic
Commutation) that manage the motor according to the 0÷10V proportional
signal coming from the microprocessor control.
Maintenance-free bearings
IP54 enclosure class.
 

REFRIGERANT CIRCUIT
Reversing valve for refrigerant circuit inversion.
Double thermostatic expansion valve.
Liquid receiver.
Check valve.
Sight glass.
Filter dryer on liquid line.
Safety valve on high and low pressure side.
Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure.
R410A refrigerant charge.

HYDRAULIC ASSEMBLY
Pumping group with 1 pump, 2 poles electric motor.
Expansion tank.
Safety valve.
Manual filling assembly.
Pressure gauge.

ELECTRICAL PANEL
In accordance with EN60204-1 norms, suitable for outdoor installation, complete with:
Main switch with door lock safety from model T19 included.
Contactors for compressor..
Transformer for auxiliary circuit and microprocessor supply.
Panel with machine controls.
Power supply: 230/1/50 for M models
Power supply: 400/3/50+N for T models

CONTROL SYSTEM
Microprocessor control. The system includes:
Display for the visualization of the alarm codes, set values and temperature values.
Dynamic set point.
Compressor running hour meter.
Contact for general alarm remotization.
“Low Temperature” set for operation with chilled water production up to
-10°C.
Menu with protection password.