NEXT CW. ..... 6,4 ÷ 105 kW

MAIN FEATURES

  • Chilled water feeding precision air conditioner.
  • 15 models available, 6 versions for a wide selection opportunity.
  • Chilled water feeding.
  • Two-way chilled water valves.
  • EC plug-fans.
  • Suitable for indoor installation.

 

MAIN BENEFITS

  • Technical synergy with RC Group liquid chillers.
  • Availability of electric heater.
  • Availability of steam humidifier.
  • Availability of hot water heating coil.
  • Availability of extra circuit heating coil (only for 4R version).
  • Availability of units with separate fan section, PLUS.
  • Complete set of optional accessories: filters, plenum, panels, stand.
  • Easily of maintenance.

 

INDOOR INSTALLATION

The machines are designed for indoor installation.

 

WORKING LIMITS

Room air temperature:
140C    minimum temperature with wet bulb.
240C    maximum temperature with wet bulb. 
350C    maximum temperature with dry bulb.

Room air humidity:

  • 20%RH    minimum relative humidity.
  • 75%RH    maximum relative humidity.

 

MAIN COMPONENTS

 

FRAMEWORK

  • Base in aluminium extrusion, painted with epoxy powders.
  • Frame in galvanized steel sheet.
  • Galvanized steel sheet panels painted with epoxy powders, internally insulated with noise absorption material and seals to ensure air tight with the panels.
  • Hinged front panels with quick release removal system.
  • Total front access for routine maintenance.
  • Removable lateral and back side panels.
  • Colour: RAL 9005 for base and frame (black)
  • RAL7016 for panels (anthracite gray)

 

FILTER SECTION

Size E0:

  • Washable air filters with G2 efficiency, with cells in synthetic fibre and metallic frame (EN 779-2002).

Size E1, E2, E3, E3P, E4, E5, E6, E7, E8, E9 and all PLUS series:

  • Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN 779-2002).

COOLING SECTION

  • Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops.
  • The heat exchanger is available in 4R, 6R or 8R version. The choice must be made when ordering.
  • The heat exchangers in 6R or 8R version are not available for size E0 units.
  • 2-way motorized valve for water flow regulation with 0÷10 VDC control actuator and emergency manual control. Nominal operating pressure up to 1600 kPa and closing pressure (Δps) of 1400 kPa.
  • Frame in galvanized steel.
  • Condensate tray in  peraluman with PVC flexible discharge pipe.

 

ELECTRICAL PANEL
In accordance with EN60204-1 norms complete with:

  • Main switch with door lock safety.
  • Magnetothermic switches for fans.
  • Contactors for each load. The supply fans equipped with EC electric motor and don’t  require contactors.
  • Transformer for auxiliary circuit and microprocessor supply.

Terminals:
OUTLETS

  • voltage free deviating contact for General Alarm 1
  • voltage free contact for supply fans status. INLETS
  • Emergency unit stop with signalling on display (external alarm).
  • External enabling.
     

Power supply 230/1/50 for size E0.
Power supply 400/3/50+N for other size.

 

CONTROL SYSTEM
Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes:

  • Real time clock.
  • Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BACnet for Ethernet (SNMP- TCP/IP), BACnet for MS/TP).
  • Main components hour-meter.
  • Nonvolatile “Flash” memory for data storage in case of power supply faulty and for alarms status recording (2MB).
  • Menu with protection password.
  • LAN connection.