MAIN FEATURES
Water cooled liquid chiller in A class energy efficiency.
11 models available, for a wide selection opportunity.
Average step of 150kW.
EER up to 5,24.
ESEER up to 8,91.
Oil-free centrifugal compressors with magnetic levitation bearings.
Inverter driven.
R134a Refrigerant charge.
Single refrigerant circuit.
Electronic expansion valve.
Shell and tube condenser.
Flooded evaporator.
Suitable for indoor installation.
MAIN BENEFITS
Up to four centrifugal compressors with magnetic levitation bearings on
the refrigerant circuit for an high efficiency.
No need of power factor correction.
Minimum starting current (LRA)
High EER and ESEER. A Class energy efficiency.
Quiet operation.
Microprocessor control system with 7” touch screen display.
Extremely easily of maintenance.
Complete set of components dedicated to the safety of the unity.
Eurovent Certification.
INDOOR INSTALLATION
The machines are designed for indoor installation.
MAGNETIC LEVITATION CENTRIFUGAL COMPRESSOR
The TURBO FL liquid chillers are equipped with two-stage centrifugal compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in a narrowing of the cooling load. The compressors of the TURBO FL liquid chillers are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication.
A CLASS ENERGY EFFICIENCY
The best and most accurate components applied to the chillers.
WORKING LIMITS IN COOLING MODE
Chilled water outlet temperature: 4÷18°C Condenser outlet water temperature: 20÷52°C
the integrated cooling circuit.
Electric motor thermal protection via internal winding temperature sensors.
Electronic integrated control for operation and alarms status.
Sensor on refrigerant discharge for temperature monitoring.
Inner sensors for electronic components and inverter temperature control.
Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply.
Degree of protection: IP54.
Menu with protection password.
HYDRAULIC CONNECTIONS OF HEAT EXCHANGERS
The hydraulic connections with flange (FL) are not supplied with counter flange.
The hydraulic connections with grooved end are not supplied with flexible
joint (optional accessory).
EVAPORATOR
Flooded shell and tube evaporator, optimized for R134a refrigerant.
Version two passes, characterized by low pressure losses on the water side.
Water tubes with a helical rifled internal surface.
Integrated liquid drop separator.
Shell, header, tube sheets made of carbon steel, tubes in Cu.
Anticondensate insulation made of polyurethane.
Temperature sensors on water inlet and outlet.
Water flow switch for water flow control.
Large liquid level indicator
CONDENSER
Shell and tube 2-passes condenser optimized for R134a refrigerant.
Machine type P4: 4-passes condenser.
Shell, header, tube sheets made of carbon steel, tubes in Cu.
REFRIGERANT CIRCUIT
Components for each refrigerant circuit:
Capacitive level sensor connected to the driver of the expansion valve.
Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. Double electronic expansion valve from model 1140 T3 included up to model 1840 T4.
Electronic by-pass valve for compressor start.
Non return valve on by-pass line for compressor start.
Sight glass.
Filter dryer on liquid line.
Service valve on liquid line.
Service valve on gas discharge.
Non return valve on gas discharge.
Safety valve on low pressure side.
Safety valve on high pressure side.
Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure.
High pressure safety switch with manual reset.
Refrigerant circuit with copper tubing with anticondensate insulation of the suction line for models 280 T1, 560 T2, 840 T3.
Refrigerant circuit with steel tubing with anticondensate insulation of the suction line for models 380 T1, 460 T1, 760 T2, 920 T2, 1140 T3, 1380 T3,
1520 T4, 1840 T4..
Plastic capillary hoses for pressure sensors connection.
R134a refrigerant charge.